Free Shipping on Equipment & Parts orders of $200 or more! * Click for Restrictions

Have a question? 800-440-6723 International: 803-252-0100

English Se habla español
Parts › PartFinder › Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 › Operator manual
Form 1220_SN_39_thru_46_01, Rev. 2007
Kaivac · Cleaning machine

Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual

1220_SN_39_thru_46_01 Rev. 200731 pagesKaivac 1220 Manual (Serial Numbers 39-46); Kaivac 1250 Manual (Serial Numbers 717-762) (KV1220, KV1250)
Free to read, no account neededEvery page has its own linkPart numbers link to the part
COVER

KaiVac® 1200 Series Operator and Parts Manual

Serial #s 1220-39 on
1250-717 on‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​‌​​​‌​⁠​​‍​​‌‌⁠‍‌‌​‍‍‌⁠​‌‌‍‍⁠​‌‌⁠

Yellow and black KaiVac 1200 Series cleaning machine on wheels, with hoses and a spray wand hanging on its sides and a gray vacuum hose curving over the top

© 2007 Kaivac, Inc. All Rights Reserved.

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 1, used with permission. SES ref PF-7K4C-4SLY‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​‌​​​‌​⁠​​‍​​‌‌⁠‍‌‌​‍‍‌⁠​‌‌‍‍⁠​‌‌⁠
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 1 of 31
READ FIRST

Read First

INSTALL DATE

Please fill out card for future records‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​‍​​​‌​⁠​​​‌⁠‌​​‍‌⁠⁠‍⁠‌‌‍‍⁠⁠⁠⁠​⁠‌‍

Install date____________________
Serial No.____________________

In short Read this manual before operating the machine. The machine works at its best when it is operated as described, maintained regularly, and kept up with manufacturer parts only.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​‍​​​‌​⁠​​​‌⁠‌​​‍‌⁠⁠‍⁠‌‌‍‍⁠⁠⁠⁠​⁠‌‍

Read this manual prior to operation. This machine will operate at its optimal efficiency if:

  • The machine is operated as described in this manual.
  • The machine is maintained properly and regularly-per maintenance instructions.
  • The machine is maintained with manufacturer parts only.

Carefully unpack and inspect your new KaiVac cleaning machine for shipping damage. Each unit is tested and thoroughly inspected before shipping. For instructions regarding shipping damage, contact Kaivac, Inc. immediately. All returns must have a Return Authorization Number (RAN), which is available by calling the Kaivac, Inc. Customer Service Department. Remember to protect your investment by registering your Warranty online at www.kaivac.com or mailing/faxing in the form on page ii.

TABLE OF CONTENTS

Getting Started

TopicPage
Limited Warranty Protection Plani
Warranty Registration Formii
Introduction1
Safety Precautions2-3

Operating your KaiVac

TopicPage
Out of Box Setup Instructions4
Preparing your KaiVac for use5
Operating your KaiVac using the S-I-M-P-L-E Process6

Maintaining your KaiVac

TopicPage
Machine Maintenance7
Black Box Removal Instructions9
Troubleshooting10-12
Machine Diagrams13-21
Parts Listings22-25

© 2007 Kaivac, Inc. All Rights Reserved.

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 2, used with permission. SES ref PF-LTMU-5HI4‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​‍​​​‌​⁠​​​‌⁠‌​​‍‌⁠⁠‍⁠‌‌‍‍⁠⁠⁠⁠​⁠‌‍
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 2 of 31
LIMITED WARRANTY PROTECTION PLAN

Limited Warranty Protection Plan

In short This warranty covers defects in workmanship or materials under normal use from the date of purchase. Coverage periods depend on whether only Kaivac chemicals, approved non-Kaivac chemicals, or unapproved chemicals are used, and all claims need a Return Authorization Number (RAN).‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​⁠​​​‌​⁠​​‍‍​⁠⁠​​⁠⁠‌​‌​​⁠‌‌​‍‍‍‍‍⁠

The KaiVac has been engineered and tested to provide long lasting performance. This warranty covers defects in workmanship or materials under normal use and service from the date of purchase.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​⁠​​​‌​⁠​​‍‍​⁠⁠​​⁠⁠‌​‌​​⁠‌‌​‍‍‍‍‍⁠

Kaivac, Inc. warrants the following components to be free from defects in materials and workmanship for these time periods:

  1. Extended Warranty for end users who use only Kaivac chemicals for the life of the machine.
    • 5 years on rotationally molded parts
    • 3 years on other parts (excluding wear items)
    • 1 year on labor
  2. Standard Warranty (for approved non-Kaivac chemicals)
    • 1 year parts and labor
  3. Chemicals that have not been approved by Kaivac. (If uncertain, please call Kaivac to check.)
    • No warranty

All KaiVac replacement parts are guaranteed for 90 days from the date of installation. Normal wear items such as wheels, hoses, seals, gaskets, cords, casters, squeegees and GFCI are excluded from warranty coverage.

All warranty claims must be accompanied by a Return Authorization Number (RAN), which is available by calling the Kaivac, Inc. Customer Service Department. No returns will be accepted without a RAN.

This warranty does not apply to return freight costs, damage or defect caused by accident, negligence, misuse, fire or repair done by anyone other than a Kaivac authorized repair center. In no event shall Kaivac, Inc. be liable for incidental or consequential damages, or any damages to persons or property.

Please Note: Under no circumstances will the seller be liable for any loss, damage, expenses or consequential damages arising in connection with the use or inability to use seller’s product. Kaivac, Inc. reserves the right to make changes or improvements to its equipment without notice. Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty is in lieu of any other warranty expressed or implied, including any warranty of merchantability or fitness for a particular purpose.

© 2007 Kaivac, Inc. All Rights Reserved.

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 3, used with permission. SES ref PF-BZPV-ZAJZ‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​​⁠​​​‌​⁠​​‍‍​⁠⁠​​⁠⁠‌​‌​​⁠‌‌​‍‍‍‍‍⁠
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 3 of 31
WARRANTY

Warranty Registration Form

In short This form is filled in by the customer who buys the equipment and must be mailed or faxed back within ten days of purchase. It collects purchaser details, the model and serial number, business type and intended uses, and it is returned to Kaivac, Inc.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌​​​​‌​⁠​​⁠‍⁠⁠​​‍‌⁠‌‍⁠⁠‍⁠‍⁠‌‌​​‍‍​

To be completed and mailed or faxed by the customer purchasing equipment. Return this warranty card within ten days of purchase.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌​​​​‌​⁠​​⁠‍⁠⁠​​‍‌⁠‌‍⁠⁠‍⁠‍⁠‌‌​​‍‍​

Purchased By:

  • Name
  • Title
  • Company
  • Street Address
  • City
  • State
  • Zip Code
  • Phone Number
  • Fax
  • Date Purchased
  • Name of Distributor

I would like to receive updated information Yes / No

Email address:

  • KaiVac® 1550 (KaiZen™)
  • KaiVac® 1750
  • KaiVac® 1220
  • KaiVac® 1720
  • KaiVac® 2150
  • KaiVac® 1250

Serial Number

Type of Business

  • School/University
  • Hospital/Health Care
  • Contract Cleaner
  • Industrial
  • Office
  • Other

Intended Uses (check all that apply):

  • Restroom Cleaning
  • Floor Stripping
  • Kitchen Cleaning
  • Carpet Extraction
  • Cleaning Around Machinery
  • Stairwell Cleaning
  • Locker and Shower Room
  • Hallway Cleaning
  • Classroom Cleaning
  • Other

Thank you for registering for our warranty program. As our way of saying thanks, we'd like to send you a free microfiber KaiTowel™.

Please return completed forms to:

Kaivac, Inc.
401 S. Third Street
Hamilton, OH 45011

Or Fax to: (513) 887-4601

© 2006 Kaivac, Inc. All Rights Reserved.

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 4, used with permission. SES ref PF-SQ3G-JNTO‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌​​​​‌​⁠​​⁠‍⁠⁠​​‍‌⁠‌‍⁠⁠‍⁠‍⁠‌‌​​‍‍​
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 4 of 31
Introduction

Introduction

Inspection

In short This section covers what to do when you receive the machine, the do's and don'ts for safe use, and the grounding requirements. Check the unit for shipping damage, follow the listed warnings, and plug it only into a properly grounded outlet.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌‌​​​‌​⁠​​⁠​​‌⁠‍‍⁠​‌‍‍​​​​​⁠⁠​‍⁠​‌

Carefully unpack and inspect your new KaiVac cleaning machine for shipping damage. Each unit is tested and thoroughly inspected before shipping. For instructions regarding any shipping damage, contact Kaivac, Inc. immediately. All returns must have a Return Authorization Number (RAN), which is available by calling the Kaivac, Inc. Customer Service Department.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌‌​​​‌​⁠​​⁠​​‌⁠‍‍⁠​‌‍‍​​​​​⁠⁠​‍⁠​‌

Warnings

DO NOT operate with a frayed, worn or damaged electrical cord.
DO NOT use to pick up flammable or combustible materials.
DO NOT run the pump without water in the water tank.
DO NOT use hot water.
DO NOT remove the float shutoff.
ALWAYS test chemicals for compatibility on surfaces to be cleaned.
ALWAYS winterize your Kaivac equipment between uses if it will be exposed to freezing temperatures.

Grounding Instructions

THE KAIVAC MUST BE GROUNDED. If it should malfunction or stop working, grounding provides a path of least resistance for the electrical current and reduces the risk of electrical shock. The KaiVac is equipped with a ground fault circuit interrupter (GFCI) to further reduce danger of electric shock. It must be maintained and tested regularly. An equipment grounding cord and plug is included with the unit. The plug must be inserted in an appropriate outlet that has been properly installed and grounded in accordance with all local codes and ordinances. Cutting off the ground wire or using a cord with an ungrounded plug will void the warranty on the unit, and Kaivac, Inc. will NOT accept responsibility for the unit.

Improper connection of the equipment grounding cord can result in the risk of electrical shock. Ask a qualified electrician or service person to check the outlet grounding if you are unsure. Do not modify the plug provided with the KaiVac. If it will not fit the outlet, have a properly grounded outlet installed by a qualified electrician.

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 5, used with permission. SES ref PF-SEZS-6ODJ‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌‌​​​‌​⁠​​⁠​​‌⁠‍‍⁠​‌‍‍​​​​​⁠⁠​‍⁠​‌
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 5 of 31
Safety Precautions

Safety Precautions

In short This section lists the safety rules for using the KaiVac: get proper training, use the equipment only as specified, use a GFCI, wear protective gear, and protect the pump from dry running, hot water and clogged filters. It also explains how to winterize the machine.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌‍​​​‌​⁠​​⁠‍‍‍​​⁠⁠​⁠​​‍‍‌⁠‍‍‍⁠​⁠‍‍

Equipment Warning

  • Read all instructions to ensure safe operation of the KaiVac.

Training

  • Proper training is required before using the KaiVac. Contact your authorized Kaivac distributor for training information.
  • Instruction placards are attached to each KaiVac and should not be removed.
  • These placards show proper cleaning procedures and safety precautions.

Equipment Use

  • Use the equipment for the purposes specified by the manufacturer. Do not use the equipment for any other purpose.
  • See the S-I-M-P-L-E operation section for proper use of equipment.

Spray Gun

  • Never point the spray gun at people.

Prevention of Electrocution

  • Use the ground fault circuit interrupter (GFCI) with the KaiVac at all times.
  • Test the GFCI before each use.
  • Do not spray liquid from the KaiVac onto electrical outlets or on any electrical devices.

Personal Protection

  • Wear gloves, eye protection and ear protection when operating the KaiVac.

Machine Integrity

  • Do not run the pump dry. This will void the machine warranty.
  • Do not run hot water through the pump. This can cause pump cavitation and will void the warranty.
  • Always be sure the water tank and water line filters are clear of debris. Running the pump with clogged filters can cause pump damage.
  • Replace any damaged cords before use.

Winterize Your Kaivac Equipment

  • Your Kaivac machinery should be winterized between uses if it is to be exposed to freezing temperatures.
  • To winterize your machine:
    • Pour 1/2 gallon of windshield wiper fluid into the empty water tank.
    • Aim the spray gun into the water tank.
    • Run the pump and spray the gun until the fluid begins running through.
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 6, used with permission. SES ref PF-XARR-OJXK‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌‍​​​‌​⁠​​⁠‍‍‍​​⁠⁠​⁠​​‍‍‌⁠‍‍‍⁠​⁠‍‍
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 6 of 31
SAFETY

Chemical use

In short This page covers safe use of chemicals, the power cord and building surfaces. Use only approved chemicals, keep them out of the water tank, plug into a grounded outlet, and check that surfaces are water-safe before cleaning.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌⁠​​​‌​⁠​​​‍​‍‍‌​⁠​⁠‌‍‍⁠‍⁠‌‍​‍​​‌​
  • Only use chemicals approved for use with the KaiVac. Use of non-Kaivac chemicals may cause machine damage and will reduce warranty periods. Turn chemical line off when not in use.
  • Keep the appropriate chemical MSDS on hand at all times.
  • Cleaning chemicals should not be put in the water tank (with the exception of KaiDri in small amounts). Chemicals in the water tank can harm operator and machine because:
    • Chemicals in the water tank must pass through the pump, which may cause premature pump failure.
    • Use of chemicals in the water tank voids the warranty.
    • Chemicals in the water tank will be aerosolized and may harm the operator.

Electrical

  • Connect to a properly grounded outlet only.
  • Do not pull the KaiVac by the cord or use the cord as a handle.
  • Do not close a door on the cord or pull the cord around sharp edges or corners.
  • Do not run over the cord.
  • Keep the cord away from heated surfaces.
  • Turn off the unit before unplugging.
  • Do not pull on the cord to unplug. Grasp the plug at the outlet and pull.

Prevention of Water Damage to Buildings

The KaiVac is to be used on water resistant building surfaces only. These include concrete, terrazzo, ceramic tile and quarry tile.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌⁠​​​‌​⁠​​​‍​‍‍‌​⁠​⁠‌‍‍⁠‍⁠‌‍​‍​​‌​

The KaiVac may be used for stripping on vinyl composite tile floors, but daily cleaning of resilient flooring using the KaiVac is not recommended.

Never overflow the water tank or the vacuum recovery tank.

Discontinue use if any leaks occur in the KaiVac.

CAUTION: Prior to cleaning, always inspect area to ensure that the surfaces to be cleaned are water-safe. In addition, check for poor construction, damaged walls and floors, missing or damaged tiles or grout, missing or insufficient caulk, and loose wall coverings. If problems are discovered, resolve them prior to cleaning in order to avoid any harm that may result from exposure to water or cleaning solution.
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 7, used with permission. SES ref PF-3K55-R7XI‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‌⁠​​​‌​⁠​​​‍​‍‍‌​⁠​⁠‌‍‍⁠‍⁠‌‍​‍​​‌​
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 7 of 31
OUT OF BOX SETUP

Out of Box Setup Instructions

In short This page shows six steps for getting the machine ready after unboxing: assembling the vac wand, fitting the plastic elbow and vac motor hose, stowing the tools, putting the brush head on the handle, and hanging the tote bag.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍​​​​‌​⁠​​​‌‍⁠⁠‍‌‌‍‌​​‌‍​‌​​‌⁠​​‌‌
Step 1: top view of the machine with an arrow pointing to the side where the vac wand sections are stored, and two wand sections being pushed together with arrows until the locking pin engages
1

1. Remove vac wand sections from the sides of machine and attach together until locking pin engages as shown.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍​​​​‌​⁠​​​‌‍⁠⁠‍‌‌‍‌​​‌‍​‌​​‌⁠​​‌‌

Step 2: the plastic elbow with rotating arrows being lowered onto the opening in the top of the vac tank of the yellow machine
2

2. After removing machine from container, attach the plastic elbow to the vac tank as shown above.

Step 3: the vac motor hose with its small hose cuff being lowered by an arrow onto the barb at the top of the machine
3

3. SMALL HOSE CUFF
Attach vac motor hose to barb and vac motor inlet as shown above.

Step 4: tools being lifted out of the vac tank with an arrow showing them going to their storage locations on the machine
4

4. Remove the tools from the vac tank and place them in the appropriate locations as shown above.

Step 5: a brush head with arrows showing the telescoping handle being threaded into it
5

5. Place the brush head onto the telescoping handle located on the left side of machine as shown above.

Step 6: the vac lid being placed onto the vac tank of the machine, with the telescoping handle and brush head standing at the left side
6

6. Make sure all tools are removed from vac tank and replace vac lid on vac tank as shown above. Place tools in tote bag and hang bag over nose of machine.

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 8, used with permission. SES ref PF-Y4WY-ZDMS‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍​​​​‌​⁠​​​‌‍⁠⁠‍‌‌‍‌​​‌‍​‌​​‌⁠​​‌‌
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 8 of 31
PREPARING YOUR KAIVAC FOR USE

Preparing your KaiVac for use

In short This section lists the five checks to make before you start cleaning. Fill the machine with water, prepare the cleaning solution, check tools and supplies, inspect hoses and spray lines, and test the GFCI.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍‌​​​‌​⁠​​⁠⁠​‍‍⁠‍‍⁠⁠‌​‌‌‌‍​‍‍⁠‌‍⁠⁠
  1. Fill machine with clean, cool water.
    Hand holding a hose over the fill opening of the yellow machine to fill it with water
  2. Prepare the cleaning solution you will be using by attaching the chemical feed line and cap to the top of your chemical bottle and selecting the proper metering tip. (See placards for metering tip information.)
    Chemical bottle with the feed line and cap attached to its top, the cap area highlighted
  3. Check machine for all tools and supplies needed to complete task.
    Yellow machine seen from above with a tool stored in the holder, for checking tools and supplies
  4. Check all hoses and spray lines for damage prior to use. If damage is found, do not continue until proper repairs are completed.
    Gloved hands checking a hose for damage, with a spot on the hose highlighted
  5. Plug in machine and test GFCI (Ground Fault Circuit Interrupter) to ensure it is working properly. You are now ready.
    Power cord plugged into a wall outlet with the GFCI box held in gloved hands, Reset button labeled
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 9, used with permission. SES ref PF-DEQC-WTI5‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍‌​​​‌​⁠​​⁠⁠​‍‍⁠‍‍⁠⁠‌​‌‌‌‍​‍‍⁠‌‍⁠⁠
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 9 of 31
S.I.M.P.L.E. No-Touch Cleaning Process

S.I.M.P.L.E. No-Touch Cleaning Process

In short This page is a picture guide to the six steps of the No-Touch Cleaning Process: Set-up, Inject chemicals, Manual brush (optional), Pressure wash and rinse, Loop spray line, and Extract and dry. Each step is shown in drawings with short labels.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍‍​​​‌​⁠​​⁠⁠​⁠‌​‍‌‌​⁠⁠‌⁠​‍‍​‍⁠⁠‍‍‌

Set-up

  1. Fill with clean, cool water.
  2. Add 1 cap of KaiDri (for spot-free rinsing).
  3. Select metering tip and insert into cap barb.
Set-up step in three drawings: water being poured into the yellow machine tank, one cap of KaiDri added to the tank, and a metering tip being selected and inserted into the cap barb of a chemical bottle
Set-up

Inject chemicals

Chemicals. Fan spray. LOW Pressure Mode.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍‍​​​‌​⁠​​⁠⁠​⁠‌​‍‌‌​⁠⁠‌⁠​‍‍​‍⁠⁠‍‍‌

Inject chemicals step: the spray gun switched to LOW Pressure Mode with the chemicals and fan spray directions marked by arrows, a fan spray aimed at a urinal, and a worker applying chemical to a tiled floor
Inject chemicals

Manual brush (optional)

Manually brush heavily soiled areas.

Optional manual brushing step: a worker brushing a floor with a long-handled brush, a worker crouching to scrub under a counter, and a worker brushing stairs
Manual brush (optional)

Pressure wash and rinse

Fresh Water. Fan spray. HIGH Pressure Mode. Pinpoint Spray. Top to Bottom.

Pressure wash and rinse step: the spray gun in HIGH Pressure Mode with fresh water and fan spray arrows, a pinpoint spray aimed into a toilet bowl, and a worker rinsing stairs from top to bottom beside the machine
Pressure wash and rinse

Loop spray line

Clockwise. Hook. Adjust last loop (if needed).

Loop spray line step: a worker coiling the spray hose clockwise around the machine, the hose looped on the machine, and the spray gun hung on a hook with the last loop adjusted if needed
Loop spray line

Extract and dry

Extract and dry step: a worker using the vacuum tool on a floor near urinals, a worker crouching to vacuum under a counter, and a worker vacuuming stairs with the machine beside them
Extract and dry

© 2007 Kaivac, Inc. All Rights Reserved

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 10, used with permission. SES ref PF-BSEF-PFHM‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍‍​​​‌​⁠​​⁠⁠​⁠‌​‍‌‌​⁠⁠‌⁠​‍‍​‍⁠⁠‍‍‌
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 10 of 31
Machine Maintenance

Machine Maintenance

In short This section lists what to check on each part of the machine: floor squeegee, spray gun, pressure hose, water tank, vacuum tank, leaks and the electrical system. Keep the machine unplugged before lifting the electric cover assembly, and stop using it if there are leaks until they are repaired.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍⁠​​​‌​⁠​​‌⁠​​⁠‍​​‍‌‌⁠⁠⁠⁠‍‌‍⁠⁠​‍⁠‍
CAUTION Always make sure machine is unplugged before lifting electric cover assembly.
ItemProcedure
Floor Squeegee
  • Check condition of rubber squeegee blades and wheels on the floor tool.
  • Rough floor surfaces will cause the blades and wheels to wear out more quickly. Replace as necessary.
Spray Gun
  • Check spray pattern. If spray pattern will not pinpoint, clean orifice by removing it with an Allen wrench and flushing. Replace if not pinpointing.
  • If nozzle becomes difficult to move from high to low pressure lubricate nozzle with lithium grease.
Pressure Hose
  • Wipe clean after each use.
  • Check for cuts or frays in the hose jacket, particularly at the end of the fittings. Replace hose if cuts are found.
Water Tank
  • Check condition of filter in water tank. Clean as needed.
  • Empty the water tank to prevent mildew and bacteria growth. Empty tank by dipping the vacuum hose onto the water tank and transferring the water to the vacuum tank.
Vacuum Tank
  • Empty and flush vacuum tank.
  • Clean and disinfect.
  • Check the float shutoff screen to be sure it is not plugged up. A plugged filter screen restricts airflow and results in reduced suction.
Leaks
  • Be alert for leaks around hoses, fittings, spray wand, tanks or elsewhere.
  • Discontinue use until leaks are repaired.
Electrical System
  • The ground fault circuit interrupter (GFCI) must be tested before each use.
  • Electric cords must be inspected for tears or cuts in the insulation.
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 11, used with permission. SES ref PF-OSGZ-GODO‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​‍⁠​​​‌​⁠​​‌⁠​​⁠‍​​‍‌‌⁠⁠⁠⁠‍‌‍⁠⁠​‍⁠‍
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 11 of 31
Black Box Removal Instructions

Black Box Removal Instructions

In short This section shows how to take the black box off the machine in four steps. Remove all hoses, cords and tools, lay the machine on its back and take out the four wingbolts, tilt the tanks upright, then disconnect the water and return lines.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠​​​​‌​⁠​​‍‍⁠‌‍‍‌‍⁠⁠​⁠‌‌‌⁠‍‌​‍⁠‌‍⁠
  1. Remove all hoses, cords, and tools prior to black box removal.
    Step 1: upright yellow machine with hoses and cords attached, next to a separate wand tube and a floor tool lying beside it that are to be removed
    1
  2. Laying the machine on its back remove the four yellow wingbolts as shown above.
    Step 2: machine laid on its back with arrows pointing to the four yellow wingbolts to be removed
    2
  3. Placing your foot on one of the two handles, tilt the yellow tanks upward until standing upright.
    Step 3: black box lying flat while the yellow tanks are tilted upward, a curved arrow showing the tilt to upright
    3
  4. Locate and disconnect the water line and return line behind the black box on the machine.
    Step 4: tanks standing upright with arrows pointing to the water line and return line behind the black box
    4
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 12, used with permission. SES ref PF-Y2GL-WYNP‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠​​​​‌​⁠​​‍‍⁠‌‍‍‌‍⁠⁠​⁠‌‌‌⁠‍‌​‍⁠‌‍⁠
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 12 of 31
Troubleshooting

Troubleshooting

In short This section is a table of problems, possible causes and solutions for the electrical, vacuum, blow dry and optional DVD systems. Always make sure the machine is unplugged before lifting the electric cover assembly.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠‌​​​‌​⁠​​‍​‌⁠‌⁠⁠⁠⁠⁠​​​​​‌⁠⁠​​​⁠⁠​
CAUTION Always make sure machine is unplugged before lifting electric cover assembly.
AreaProblemPossible CauseSolution
ElectricalNo power to pump or vac motor.1. Machine not plugged in.
2. Switch not on.
3. GFCI tripped.
4. Building circuit overloaded.
5. Switch wires loose.
6. Connections loose.
1. Plug machine in.
2. Check switches for "on."
3. Test and reset GFCI.
4. Check and reset circuit.
5. Disconnect power and check for loose wire.
6. Disconnect power and check for loose wire under panel.
Electrical burning smell.1. Vac motor brushes worn.
2. Vac motor hung up.
3. Pump motor hung up.
1. Remove vac motor and repair.
2. Release pressure on hose and jog pump switch, or replace.
Vacuum SystemNo/Weak vacuum.1. Vac tank full.
2. Squeegee blades or wheels worn.
3. Float shutoff screen dirty.
4. Float ball stuck.
5. Damaged hose.
6. Dump hose plug missing.
7. Access lid not tight.
8. Vacuum hose plugged.
9. Too much liquid in vac hose.
10. Vac hose still wrapped.
11. Muffler plugged.
12. Leak in vac tank.
1. Empty vac tank.
2. Replace wheels or blades and check periodically.
3. Wipe off float screen to clean.
4. Tap float and release/clean.
5. Cut and repair/replace.
6. Contact dealer and replace.
7. Tighten lid hand tight.
8. Flush hose to remove debris.
9. Allow air in when vacuuming.
10. Unwrap vac hose fully.
11. Remove HEPA filter and clean.
12. If repairable, clean and dry affected area and seal with silicone.
Moisture from exhaust.1. Vac tank full.
2. Float shutoff missing.
3. Excessive foam in vac tank.
1. Dump vac tank.
2. Replace.
3. Use defoamer.
Blow Dry SystemNo air flow.1. Hose disconnected.1. Reconnect hose.
Moisture from nozzle.1. Water in blow hose.1. Dry blow line.
Suction, not blow action.1. Vacuum hose connected to vac tank.1. Reconnect to vac motor exhaust hose.
DVD System (optional)No power.1. Power cord not connected
2. Power switch not on.
1. Plug cord into DVD player.
2. Turn switch on DVD player on.
No picture.1. Screen is blank.1. Close and re-open lid. Play.
No audio.1. No sound from player1. Check volume control knob.
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 13, used with permission. SES ref PF-RR4T-CFIX‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠‌​​​‌​⁠​​‍​‌⁠‌⁠⁠⁠⁠⁠​​​​​‌⁠⁠​​​⁠⁠​
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 13 of 31
TROUBLESHOOTING

Troubleshooting

In short This table lists problems with the high pressure system and the chemical injection system, with the possible causes and the matching solutions for each. Always unplug the machine before lifting the electric cover assembly.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠‍​​​‌​⁠​​‌‍​‍⁠‍‍‌​‍‌⁠‌​​‌‌⁠​‌​⁠‌‌
CAUTION Always make sure machine is unplugged before lifting electric cover assembly.
AreaProblemPossible CauseSolution
High Pressure SystemNo water from pump or low pressure.
  1. Out of water.
  2. Gun nozzle plugged.
  3. Air in pump (vapor lock).
  4. Gun orifice missing.
  5. Water tank filter plugged.
  6. In-line bowl filter plugged.
  7. Bowl filter lid loose.
  8. Pressure hose damaged.
  9. Quick disconnect leaking.
  10. Injector plugged.
  11. Pulse hose damaged.
  12. Regulator failed.
  13. Hose kinked.
  14. Seals in pump need replaced.
  1. Fill water tank.
  2. Remove orifice with Allen wrench and clean.
  3. Use power prime technique.
  4. Replace orifice.
  5. Clean tank and filter.
  6. Remove filter cover and clean.
  7. Gently tighten bowl cover.
  8. Repair or replace.
  9. Tighten or replace.
  10. Remove safety cap from chemical and blow small amounts of compressed air into line.
  11. Repair or replace.
  12. Replace.
  13. Unkink and check for damage
  14. Remove and replace seals.
Bad fan pattern or pinpoint pattern on gun.
  1. Debris in nozzle.
  2. Orifice damaged.
  1. Remove orifice with Allen wrench and clean.
  2. Remove and replace.
Chemical Injection SystemNo chemical flow.
  1. Out of chemical.
  2. Safety cap not secure.
  3. Chemical valve "off."
  4. Safety cap plugged.
  5. Spray gun in wrong mode.
  6. Metering tip plugged.
  7. Injector plugged.
  8. Air entering system.
  9. Injector installed backwards.
  1. Refill chemical.
  2. Check safety cap / tighten.
  3. Check on / off valve.
  4. Replace cap.
  5. Make sure gun nozzle is pulled out away from gun chemical mode.
  6. Check metering tip for clog.
  7. Remove safety cap from chemical and blow small amounts of compressed air into line.
  8. Check for air entering system around chemical lines or injector.
  9. If fluttering or pulsing sound can be heard while spraying or when machine is running it is possible that your injector is in backwards. Remove and reinstall.
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 14, used with permission. SES ref PF-3NS2-CQRA‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠‍​​​‌​⁠​​‌‍​‍⁠‍‍‌​‍‌⁠‌​​‌‌⁠​‌​⁠‌‌
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 14 of 31
Troubleshooting

Troubleshooting

CAUTION Always make sure machine is unplugged before lifting electric cover assembly.
In short This chart lists problems by machine area, with the possible causes and the fix for each. This page covers the chemical injection system (continued), the dump system, wheels and casters, and the squeegee head.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠⁠​​​‌​⁠​​‌‍​‍‍‍⁠‌​⁠‍‍​⁠‍‌‌‌‍‌​⁠​‍
AreaProblemPossible CauseSolution
Chemical Injection System Cont'd.Not enough chemical flow.
  1. Metering tip plugged.
  2. Wrong metering tip.
  1. Remove and clean.
  2. Check and replace per chart.
Chemical line blows off safety cap.
  1. Debris in injector.
  1. Remove safety cap from chemical and blow small amounts of compressed air into line.
Water backflows into chemical bottle.
  1. Bad seat on injector check valve.
  2. Bad safety cap.
  1. Check injector o-ring or replace.
  2. Replace safety cap.
Dump SystemDump hose will not empty tank.
  1. Dump hose plug not removed.
  2. Clog in bottom of tank.
  1. Remove plug.
  2. Tip dump contents, remove debris.
Dump hose leaks.
  1. Hose cut.
  2. Clamp loose.
  3. Dump plug bushing missing.
  4. Plug missing.
  1. If leak is less than 4" from tank side, cut and reattach, or replace.
  2. Tighten hose clamp.
  3. Replace bushing.
  4. Replace plug.
Wheels and CastersWheels won’t roll, or they rub.
  1. Flat tires.
  2. Debris wrapped around axle.
  3. Bearings tight.
  4. Wheels too loose on axle.
  5. Bearings falling out.
  1. Inflate tires to 30 p.s.i.
  2. Check for debris on axle.
  3. Grease bearings.
  4. Remove wheel, add washers to take up slack.
  5. Replace bearing assembly.
Squeegee HeadFloor streaks.
  1. Worn blades or wheels.
  1. Replace wheels and / or blades.
Squeegee head doesn’t easily rotate when installed on wand.
  1. Brass ring on wand not in groove.
  2. Coupling nut too tight.
  1. Loosen coupling nut and re-position head on groove.
  2. Loosen 1/2 turn.
Head won’t stay on wand.
  1. Coupling nut cracked.
  2. Brass ring worn.
  1. Replace.
  2. Replace.
Premature blade wear.
  1. Squeegee wheels worn.
  1. Check wheels for wear / replace.
Sucks to the floor too tightly.
  1. Squeegee wheels worn.
  1. Check wheels for wear / replace.
Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 15, used with permission. SES ref PF-BETJ-WLG7‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​​⁠⁠​​​‌​⁠​​‌‍​‍‍‍⁠‌​⁠‍‍​⁠‍‌‌‌‍‌​⁠​‍
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 15 of 31
WIRING DIAGRAM

Wiring Diagram Kaivac 1200 series

In short This page shows the wiring diagram for the Kaivac 1200 series. It shows how the power cord with GFCI connects to the vacuum motor, hour meter, pump, two switches and the control module, with a color code for the wires.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​‌​​​​​‌​⁠​​​⁠⁠‍‍‍⁠⁠​‍‍‍‌‌​‍‍‌⁠⁠​‌​‌
AbbreviationMeaning
RDRED
BLBLUE
BKBLACK
WWHITE
GGREEN
GFCIGROUND FAULT CIRCUIT INTERRUPTER
Wiring diagram of the Kaivac 1200 series: power cord with GFCI at top left feeding green, white and black wires, which branch to the vacuum motor, the hour meter, the pump, two switches and a control module at right. Wires are labeled G, W, BK and RD.

© 2007 Kaivac, Inc. All Rights Reserved‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​‌​​​​​‌​⁠​​​⁠⁠‍‍‍⁠⁠​‍‍‍‌‌​‍‍‌⁠⁠​‌​‌

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 16, used with permission. SES ref PF-REZ6-VHQI‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​‌​​​​​‌​⁠​​​⁠⁠‍‍‍⁠⁠​‍‍‍‌‌​‍‍‌⁠⁠​‌​‌
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 16 of 31
TOOL ARRANGEMENT

Tool Arrangement

In short This page shows the machine from four views with its tools and parts labeled by name and part code. Use it to identify the squeegee, wands, hoses, spray gun, valve and covers.‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​‌​‌​​​‌​⁠​​‌‍⁠​⁠‍​​‍‌⁠‌​⁠​​‍⁠‌​​​⁠⁠

Front Right View

Front right view of the machine with labels: Squeegee Head (CVS12S), Vac Wand 2 Piece (CVS11A), Swivel Brush (SWBRUSH), Brush Handle (CAS03A), KaiDrain (CVS14), Dump Hose (DH26), Electric Cord, GFCI (GFCI25), and HEPA Cover (BAT1250)
Front Right View

Rear Left View

Rear left view of the machine with labels: Chemical Holder (VLJHA), Blow Nozzle (CVS13), Chemical On/Off Valve (VA2W), Spray Gun 1220 (SUBGA2) and 1250 (SUGAKW), and Spray Line (PH32)
Rear Left View

Overhead View

DryVac unit with a power cord, labeled DryVac Complete (DRYVAC), see page 21.5
DryVac Complete (DRYVAC)
Overhead view of the machine, front at top, back at bottom, left and right marked, with labels Vac Hose (VHKVJRST) and Placards (PLA1200)
Overhead View

Bottom View

Bottom view of the machine with the Bottom Cover Plate (BPLATE1200) labeled
Bottom View

© 2007 Kaivac, Inc. All Rights Reserved‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​‌​‌​​​‌​⁠​​‌‍⁠​⁠‍​​‍‌⁠‌​⁠​​‍⁠‌​​​⁠⁠

Source: Kaivac 1220 S/N 39-46 / 1250 S/N 717-762 Operator Manual 1220_SN_39_thru_46_01 Rev. 2007, page 17, used with permission. SES ref PF-3CAT-LRPE‌‌​⁠​‍‌‍​​‍⁠​‌‍⁠‍​‌​​​​​​‌​‌​​​‌​⁠​​‌‍⁠​⁠‍​​‍‌⁠‌​⁠​​‍⁠‌​​​⁠⁠
1220 S/N 39-46 / 1250 S/N 717-762 1220_SN_39_thru_46_01 (2007)Page 17 of 31

Kaivac and KaiVac are trademarks of Kaivac, Inc. Southeastern Equipment & Supply is an independent dealer.

Not Sure Which Machine Fits Your Floors?

Talk to a real SES tech about new, demo or certified reconditioned options, parts and service.

© 2026 Southeastern Equipment and Supply, Inc. All Rights Reserved.

Visa Discover AMEX Mastercard